![DL/T5210.2-2009电力建设施工质量验收及评价规程第2部分:锅炉机组(英文版)](https://wfqqreader-1252317822.image.myqcloud.com/cover/57/33689057/b_33689057.jpg)
4.8 Erection of Boiler Auxiliary Machinery
4.8.1 Inspection of main bearings of ball mill.
1 Scope:inspection of main bearings of ball mill.
2 Quality criterias and inspection methods are shown in Table 4.8.1.
Table 4.8.1 Inspection of main bearings of ball mill
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_423.jpg?sign=1738969439-CQqXMOCjX9fur4Gh5WpFofoDxw02eILK-0-e9f18b067684d405276d5d99257e4c65)
Table 4.8.1(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_424.jpg?sign=1738969439-rS5KX4zBNiux7NjzG9px4tMkyu6fpD6p-0-1b6bc0e78686197c2987af170c770cb9)
4.8.2 Inspection of large and small gears of ball mill.
1 Scope:inspection of large and small gears of ball mill.
2 Quality criterias and inspection methods are shown in Table 4.8.2.
Table 4.8.2 Inspection of large and small gears of ball mill
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_425.jpg?sign=1738969439-aSd7NXQYwkJZDewuVb76NHcTtC3115hq-0-84a1a45b2b1708962583a50b429a5fcf)
Table 4.8.2 Inspection of large and small gears of ball mill
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_426.jpg?sign=1738969439-ar9KPdYvm95W7pfU8rQfTZPTn2UudV0b-0-a3c467f1821a36fe00afe06e9572fe4a)
Table 4.8.2(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_427.jpg?sign=1738969439-xe86hsCUWo5axqtjMZhxcVrkmmRWNB8M-0-83381c8d1d0c1de8f3f7a3dde851c104)
4.8.3 Erection of main bearings of ball mill.
1 Scope:erection of main bearings of ball mill.
2 Quality criteria and inspection methods are shown in Table 4.8.3.
Table 4.8.3 Erection of main bearings of ball mill
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_428.jpg?sign=1738969439-b59aqxxa1emtQIWd70IEZV6CiVgJ2oVB-0-7047bb4d3ce83fa3ba85d0fb2eb8c9f3)
Table 4.8.3(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_429.jpg?sign=1738969439-N2pfideFva8xcW2zOqTtOh6rVkOIpKJG-0-214045e1cd251f6c2ad931332457afc6)
4.8.4 Erection of ball mill body.
1 Scope:erection of ball mill body.
2 Quality criteria and inspection methods are shown in Table 4.8.4.
Table 4.8.4 Erection of ball mill body
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_430.jpg?sign=1738969439-Nk07pvhdSBxldYBMiUwcSevgeq25tq3G-0-aa3248e22eb340e07ea4bf4d703469f1)
Table 4.8.4(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_431.jpg?sign=1738969439-KNbIWiRuuTJGaOre3q4zpO15368BLGXE-0-c858394d39faae75406749c2ca10b5a9)
Table 4.8.4(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_432.jpg?sign=1738969439-OhkXazxncJkRGN2HviJlDYaaM86XzlBv-0-55bb0041a774eefe14b23dd7761971ab)
4.8.5 Erection of transmission devices of ball mill.
1 Scope:erection of ball mill motor,reducer and barring devices.
2 Quality criteria and inspection methods are shown in Table 4.8.5.
Table 4.8.5 Erection of transmission devices of ball mill
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_433.jpg?sign=1738969439-xxAlman451pzJ6fhQFD7EjlCCRF8YGyV-0-79564e3727bb0f22bfb637cae48e3c0a)
Table 4.8.5(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_434.jpg?sign=1738969439-YZrT5eC0FLMaG6konmZJnMmOo214F7UG-0-b4b9467abacc2d50e9967c62e7d362b7)
4.8.6 Erection of ball mill oil system.
1 Scope:erection of ball mill oil system.
2 Quality criteria and inspection methods are shown in Table 4.8.6.
Table 4.8.6 Erection of ball mill oil system
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_435.jpg?sign=1738969439-QpMGL95VFhlDsNYa8NEPyxV2XzXgqvyb-0-4c0900bb16093db20d9105b6d3c9dc73)
Table 4.8.6(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_436.jpg?sign=1738969439-2NOjNnFKbxeYhPQT32Nqwfo5EQBRtuSL-0-39ba5d3c2e2fb5f8ea1ae5c097d64660)
4.8.7 Certification of hydrostatic tests of oil station cooler,bearing cooling water chamber.
1 Scope:tightness inspection of boiler auxiliary equipment in an oil system.
2 The certification contents are shown in Table 4.8.7.
Table 4.8.7 Certification of hydrostatic tests of oil station cooler,bearing cooling water chamber
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_437.jpg?sign=1738969439-jrkm0dBdLMZp7VOAPJFTztX67rl9TK9y-0-011c1aa43747467f309c8e667d429c72)
4.8.8 Construction record.
1 Scope:erection construction records of whole boiler auxiliary equipments.The specific contents may be filled.
2 The record shall meet the requirements of Table 4.8.8.
Table 4.8.8 Construction record
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_438.jpg?sign=1738969439-jNelkzPKMgAn0EcdJ1PRAkSfdN3o5IyL-0-063eba5319e06ecad3c77eda6af7978d)
4.8.9 Mill bolts tightening record.
1 Scope:thermal tightening of mill bolts.
2 Record requirements are shown in Table 4.8.9.
Table 4.8.9 Mill bolts tightening record
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_439.jpg?sign=1738969439-cIqnY1leRUtaDKRRSVkxeMq4FbkIyVym-0-e0eb9655f0d5adb34294fdd46f74e6ec)
4.8.10 Certification of closing equipment manhole.
1 Scope:closing of manhole door after cleaning of boiler auxiliary equipments and before their trial operation.
2 Certification shall meet the requirements of Table 4.8.10.
Table 4.8.10 certification of closing equipment manhole
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_440.jpg?sign=1738969439-OlcHRdQPQZlHICoJRxw04rk81n7LADa7-0-5417d9fe8cbdc84f5c933ae7a21e223d)
4.8.11 Inspection and certification before equipment trial operation.
1 Scope:inspection and certification for all rotary equipments of boiler auxiliary equipments before the trial operation.Inspection items can be added or deleted properly.
2 Certification shall meet the requirements of Table 4.8.11.
Table 4.8.11____________________Inspection and certification before equipment trial operation
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_441.jpg?sign=1738969439-GaUhWorEGc1wZke0HTw7uDlqz18swHCt-0-32623cd916b0c08d7f9f0c11ecd0fb4e)
4.8.12 Certification of equipment trial operation.
1 Scope:certification of the trial operation of whole boiler auxiliary equipments.
2 Certification shall meet the requirements of Table 4.8.12.
Table 4.8.12 Certification of equipment trial operation
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_442.jpg?sign=1738969439-eLASQxi6qHi6rG6nDBqsNzxWqEqcuVIF-0-8c4dbe761c8b5023b3849575764276a8)
4.8.13 Erection of fan mill body.
1 Scope:erection of fan mill body.
2 Quality criteria and inspection methods are shown in Table 4.8.1.
Table 4.8.13 Erection of fan mill body
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_443.jpg?sign=1738969439-0fjlF6Bske2ezeKcf4O2X6ClZNIvneqX-0-ea50a583b7c75d27fc12586c9d53d1b2)
Table 4.8.13(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_444.jpg?sign=1738969439-bMM2O1TYEbBizeYwkIhlnMdNMJAnFXSA-0-addb2cbad222327f6fdce49263c227a9)
4.8.14 Erection of Fan Mill Oil System.
1 Scope:erection of fan mill oil system.
2 Quality criteria and inspection methods are shown in Table 4.8.14.
Table 4.8.14 Erection of fan mill oil system
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_445.jpg?sign=1738969439-kOf1fVCBBS9yMd0bkz7FT6AvM8haU0sL-0-7c2c56a6df97e06d11e0b82005594db3)
Table 4.8.14(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_446.jpg?sign=1738969439-9Lpr6cp4FgSI0ieU4hkVNg7tJX3ICO83-0-80f82c5a6ef03b961396bb017389e52c)
4.8.15 Erection of fan mill transmission devices.
1 Scope:erection of fan mill transmission devices.
2 Quality criteria and inspection methods are shown in Table 4.8.15.
Table 4.8.15 Erection of fan mill transmission devices
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_447.jpg?sign=1738969439-flXTe8BuOA9aQOSCrelqbUdgKW4FiRKU-0-8622da2227f9fd0368d811a6f8916707)
4.8.16 Erection of MPS(ZGM)medium speed mill body.
1 Scope:erection of MPS(ZGM)medium speed mill body.
2 Quality criterias and inspection methods are shown in Table 4.8.16.
Table 4.8.16 Erection of MPS(ZGM)medium speed mill body
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_448.jpg?sign=1738969439-37moQlopaW7xHyjOvcNsr1OMefW1Varj-0-95450e43515a20ff2b3e1c121a8922f8)
Table 4.8.16(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_449.jpg?sign=1738969439-efDPb8gvsr10Y0maITLQvFSjTkhjag8o-0-7a3a0ecf435f1ed5a345322812cf6354)
4.8.17 Erection of MPS(ZGM)medium speed mill transmission devices.
1 Scope:erection of medium speed mill transmission devices.
2 Quality criteria and inspection methods are shown in Table 4.8.17.
Table 4.8.17 Erection of MPS(ZGM)medium speed mill transmission devices
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_450.jpg?sign=1738969439-dlQSLhIgGqKYoJ7I8PcD4ZbXeCheClZ6-0-9f70d314aa3ddc412c8266bd057d6134)
4.8.18 Erection of Medium Speed Mill Oil System.
1 Scope:erection of medium speed mill oil system.
2 Quality criteria and inspection methods are shown in Table 4.8.18.
Table 4.8.18 Erection of medium speed mill oil system
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_451.jpg?sign=1738969439-G6lYoUGcPkqjqK8iYuT3w6cBde94yGyU-0-7c50283f2aeb3b9014059a37580fb368)
4.8.19 Erection of E-type medium speed coal mill body.
1 Scope:erection of E-type medium speed coal mill body.
2 Quality criteria and inspection methods are shown in Table 4.8.19.
Table 4.8.19 Erection of E-type medium speed coal mill body
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_452.jpg?sign=1738969439-Qw19wTsXBVDXYjxHGhnIWFcyrNuAboSL-0-12ac1f5223389c954f5b1b6c29b507ec)
Table 4.8.19(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_453.jpg?sign=1738969439-08lWbKjeMYUiiJJvaEDZHeJdMYzOQ2HQ-0-a4e964573912587a63ce86c4c8322369)
4.8.20 Erection of E-type medium speed coal mill driving device.
1 Scope:erection of E-type medium speed coal mill driving device.
2 Quality criteria and inspection methods are shown in Table 4.8.20.
Table 4.8.20 Erection of E-type medium speed coal mill driving device
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_454.jpg?sign=1738969439-rfK2iwTP3XlXRSExwj582UJcWT5zY9lX-0-f01c6c01388199223c64a4179b4d7fd6)
4.8.21 Erection of RP(HP)bowl type coal mill body.
1 Scope:erection of RP(HP)bowl type coal mill body.
2 Quality criterias and inspection methods are shown in Table 4.8.21.
Table 4.8.21 Erection of RP(HP)bowl type coal mill body
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_455.jpg?sign=1738969439-XVui54oezfv7CzziBGBoxWXUwwbfrh05-0-a44e6df3eab2a3ffcbc88eeaa7923652)
Table 4.8.21(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_456.jpg?sign=1738969439-92CLJj26sbjKtlzlEGjrcRfv68qob07m-0-d7942e1044e6faba0f2cdeebcd8323cd)
4.8.22 Erection of RP(HP)bowl type coal mill transmission devices.
1 Scope:erection of RP(HP)bowl type coal mill transmission devices.
2 Quality criteria and inspection methods are shown in Table 4.8.22.
Table 4.8.22 Erection of RP(HP)bowl type coal mill transmission devices
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_457.jpg?sign=1738969439-XpWYhA9UX5K1xchVuIaIeTQatQhhnyir-0-3944358fa524a1273762230272cb52a8)
4.8.23 Erection of centrifugal fan.
1 Scope:erection of all centrifugal fans in boiler auxiliary machineries.
2 Quality criteria and inspection methods are shown in Table 4.8.23.
Table 4.8.23 Erection of centrifugal fan
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_458.jpg?sign=1738969439-b9Dhimlr3yLwXbrTtMyrEP42jql1D1Fc-0-27d929496abdab311cf3a1b6395fcc3a)
Table 4.8.23(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_459.jpg?sign=1738969439-oNu5kaq0oaEtgJB99RfMPaGt85yCvOt6-0-8c6e658c9369e51c139086298fbd534c)
Table 4.8.23(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_460.jpg?sign=1738969439-JqjirhG3ESdTU0X1bucFhpgdQXS0vQYu-0-08f610dd97a541a4f213cfe620ca3888)
4.8.24 Erection of axial flow fan.
1 Scope:erection of axial flow fans in boiler auxiliary machineries.
2 Quality criteria and inspection methods are shown in Table 4.8.24.
Table 4.8.24 Erection of axial flow fan
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_461.jpg?sign=1738969439-pWqItWMOOFM9sxzEI5GU4cnnPXpX7bhC-0-3f50ff03bcaa16ad95a488512da2c896)
Table 4.8.24(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_462.jpg?sign=1738969439-AvbVJIErPQzIcQ2X4jnxBtyzy0uRjvII-0-f65d8b56da425ed0cba5e1de1ea71f93)
4.8.25 Erection of fan motor.
1 Scope:erection of fan motors in boiler auxiliary machineries.
2 Quality criteria and inspection methods are shown in Table 4.8.25.
Table 4.8.25 Erection of fan motor
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_463.jpg?sign=1738969439-ccCR8iaEEYelLpRuA1yiBbKLIRmNcVu2-0-460781dd5139a0d943caed75dc5ad70c)
4.8.26 Erection of fan oil system.
1 Scope:erection of fans with oil system in boiler auxiliary machineries.
2 Quality criteria and inspection methods are shown in Table 4.8.26.
Table 4.8.26 Erection of fan oil system
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_464.jpg?sign=1738969439-wRnzFEXLMKsOLfLN3uHu2iyQtifyUCpm-0-cd0b14f9a874d0f0ad7901e53af7d74d)
4.8.27 Erection of high pressure fluidization fan.
1 Scope:erection of medium and high pressure fluidization fan in boiler auxiliary machineries.
2 Quality criteria and inspection methods are shown in Table 4.8.27.
Table 4.8.27 Erection of high pressure fluidization fan
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_465.jpg?sign=1738969439-84KDzwq3Xhfc7xFsHfszGY37bNXnOZMD-0-2892de2fe1815181ab891ceda19751c1)
Table 4.8.27(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_466.jpg?sign=1738969439-8XTjXOYG85cuVhKzICBPLHjLRMlu8ySx-0-6791c8adf326bf72dae0dc80212c5cda)
4.8.28 Erection of pulverized coal impeller feeder.
1 Scope:erection of pulverized coal impeller feeder.
2 Quality criteria and inspection methods are shown in Table 4.8.28.
Table 4.8.28 Erection of pulverized coal impeller feeder
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_467.jpg?sign=1738969439-0UYVcshOkRmhPI5XCFFMhshk4LcDR7JQ-0-343deabcc359d0eb6dd3b9562bcdc183)
4.8.29 Erection of pulverized coal screw conveyer.
1 Scope:erection of such type of pulverized coal screw conveyers.
2 Quality criteria and inspection methods are shown in Table 4.8.29.
Table 4.8.29 Erection of pulverized coal screw conveyer
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_468.jpg?sign=1738969439-V5kZbv0vKiArZPAFmT7LZVWFyF6WEOGT-0-874b32c179e96b0a0f3fb9105b47737f)
Table 4.8.29(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_469.jpg?sign=1738969439-Nw28ZGFYsrbmiqOZJ1Q6dyqXgbc07eIz-0-a3eefe6882e5f2a6d2760993431b942c)
4.8.30 Erection of pulverized coal scraper conveyer.
1 Scope:erection of such type of coal feeders.
2 Quality criteria and inspection methods are shown in Table 4.8.30.
Table 4.8.30 Erection of pulverized coal scraper conveyer
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_470.jpg?sign=1738969439-xpJXxm2u6RULiUO49ZhYWt09YXjamfpz-0-7ba3fa72d0b8f337680b44e5fc4c9c4e)
Table 4.8.30 (continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_471.jpg?sign=1738969439-ceoSU7ZVoJTYvegP1HDfFV781gHWWQ9u-0-95d47f97c7aa9855c07511a573b7f7f9)
4.8.31 Erection of coal vibrating feeder.
1 Scope:erection of such type of coal feeders.
2 Quality criteria and inspection methods are shown in Table 4.8.31.
Table 4.8.31 Erection of coal vibrating Feeder
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_472.jpg?sign=1738969439-WDSs9yfTpJHDLSd1V9BI2du4akvZmZhv-0-fb201fe8d03ce7087d9432f7e2f049d7)
4.8.32 Erection of coal belt feeder.
1 Scope:erection of coal belt feeder.
2 Quality criteria and inspection methods are shown in Table 4.8.32.
Table 4.8.32 Erection of coal belt feeder
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_473.jpg?sign=1738969439-PAuCXDlvszflbtzIQuUX9ppAmq5V3CKU-0-17a777dc70b08368900cfb5a5e050215)
4.8.33 Erection of air compressor.
1 Scope:erection of air compressor.
2 Quality criteria and inspection methods are shown in Table 4.8.33.
Table 4.8.33 Erection of air compressor
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_474.jpg?sign=1738969439-lQmxXMiYYVzFax6cA1O7r1y9IFIQ7kz9-0-1761d8a1fadd3531fc5b28b1c79bae33)
Table 4.8.33(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_475.jpg?sign=1738969439-TyIfkyUatdi6qBK6r68fv4RxtEZYigeN-0-af99d6c574cc65d39bc9b4a940038347)
Table 4.8.33(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_476.jpg?sign=1738969439-lFPmzw5skbFfJujlwONUKDsDPPQ4vOau-0-4df02b447345571695f5d3907f8c857b)
4.8.34 Erection of dryer.
1 Scope:erection of dryers in air compressor room.
2 Quality criteria and inspection methods are shown in Table 4.8.34.
Table 4.8.34 Erection of dryer
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_477.jpg?sign=1738969439-V17vpUvZVsFRLRKBNfIfT9WT2kpQeC9V-0-ac50b199027cde0f63e547e0f641f10e)
4.8.35 Erection of cooling water pump.
1 Scope:erection of such pumps.
2 Quality criteria and inspection methods are shown in Table 4.8.35.
Table 4.8.35 Erection of cooling water pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_478.jpg?sign=1738969439-zLBe61tF3XzeEMPbpsbAvQxwjqnSyfSG-0-ced4224c6a5e26946b8ba4eea9c4dff0)
Table 4.8.35(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_479.jpg?sign=1738969439-XBCx6zdEdbCVLDygPFXyYBXU8oP7czOb-0-06b7ccfadc9d353c7837f15baa5264f7)
4.8.36 Erection of draining pump.
1 Scope:erection of such type of pumps.
2 Quality criteria and inspection methods are shown in Table 4.8.36.
Table 4.8.36 Erection of draining pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_480.jpg?sign=1738969439-BQSt4Y4mdMwMpPgj2zOgwN82sbl4qpa2-0-6c32cc089e29cca61cccb7a57ce4490c)
Table 4.8.36(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_481.jpg?sign=1738969439-7DN41BD8q5r8oI5laxrDDYFZFotrRynQ-0-b6403f6a3e9c776ad34ba722adcdfbb7)
4.8.37 Erection of boiler forced circulating Pump.
1 Scope:erection of boiler forced circulating pump.
2 Quality criteria and inspection methods are shown in Table 4.8.37.
Table 4.8.37 Erection of boiler forced circulating pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_482.jpg?sign=1738969439-meAVPkTTENhBK5C1B7bryTYFvkXWOvpq-0-220791d75a44cf941b8053ac860cecab)
4.8.38 Erection of start-up circulation pump.
1 Scope:erection of start-up boiler circulation pump.
2 Quality criteria and inspection methods are shown in Table 4.8.38.
Table 4.8.38 Erection of Start-up circulation pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_483.jpg?sign=1738969439-6qKG2cPe3HewmGubKJ606Axedjdm1Z9O-0-50aaf14c0e233f6e92bf6ae75b934ec6)
4.8.39 Erection of Emergency Water Feed Pump.
1 Scope:erection of boiler emergency water feed pump.
2 Quality criteria and inspection methods are shown in Table 4.8.39.
Table 4.8.39 Erection of emergency water feed pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_484.jpg?sign=1738969439-hIeBx39zBOtkVu5tAHKozM0YiLaPxK6F-0-e8f4c0a7cb2e365d5acc143a055c581d)
Table 4.8.39(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_485.jpg?sign=1738969439-JGgltlCsQQSnZ3t8XyBI6pT7PPN8Ma83-0-cfe7fb35e0fa08202c5a39e7de6c378a)
4.8.40 Trial operation of pump subsection.
1 Scope:erection of all the pumps at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.40.
Table 4.8.40 Trial operation of pump subsection
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_486.jpg?sign=1738969439-TfB2pVgRjxeIehf4WQfmtqn00KCG25iR-0-a104e944a6223e622d8e31c777e7ee9e)
Table 4.8.40(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_487.jpg?sign=1738969439-y8opFs1G22tdKnIWT68zIULsJwciubAt-0-1cca37ee02f773d15ca6c8636d18bc47)
4.8.41 Erection of slag extractor.
1 Scope:Table 4.8.41-1 is suitable for the erection of boiler slag extractor;and Table 4.8.41-2 is suitable for the erection of boiler dry slag discharge equipment.
2 Quality criteria and inspection methods are shown in Table 4.8.41-1 and 4.8.41-2.
Table 4.8.41-1 Erection of slag extractor
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_488.jpg?sign=1738969439-Zv2hcl1C1ygxxeod6303k5UnU83Lmwhg-0-67552985fe5397a9cc8260e141042194)
Table 4.8.41-2 Erection of dry slag slag discharge equipment
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_489.jpg?sign=1738969439-D8BTXytWUIbHUGBtP2aaEMuHLKBSAKje-0-21d1892420962a12536696c4d1a984a5)
Table 4.8.41-2(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_490.jpg?sign=1738969439-13urERJA1dP8mPoDuqZNNfhWmmswmKyn-0-a42b69e4f557b9f52092e062a8eb993a)
Table 4.8.41-2(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_491.jpg?sign=1738969439-CnYGGDjCGE4nZoE61CfrgdAIeUXmw025-0-3349434b658ebd6058220b1efd8d55f7)
4.8.42 Erection of slag crusher.
1 Scope:erection of boiler slag crusher.
2 Quality criteria and inspection methods are shown in Table 4.8.42.
Table 4.8.42 Erection of slag crusher
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_492.jpg?sign=1738969439-V50NdlzLEZCYykIM0DQ5UuEGzFQPF5CJ-0-f0d69f22319a85d6cfdca2ce3a98428b)
4.8.43 Erection of slag conveyer.
1 Scope:erection of boiler slag conveyer.
2 Quality criterias and inspection methods are shown in Table 4.8.43.
Table 4.8.43 Erection of slag conveyer
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_493.jpg?sign=1738969439-QF3aFrc8teo9oIo7w3WMVzIBp8VWCR1R-0-4de3a55eb6c18d9b6a7c76bfed86a0cb)
Table 4.8.43(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_494.jpg?sign=1738969439-I40w1UQti4V7OrLRdYUaEivzNI5SWjuy-0-493feecb943d405c78e34941743fc147)
4.8.44 Erection of slurry pump.
1 Scope:erection of boiler slurry pump.
2 Quality criteria and inspection methods are shown in Table 4.8.44.
Table 4.8.44 Erection of slurry pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_495.jpg?sign=1738969439-XoInOZJbUt3SMF55NwZ0IYh5HTBeCc0y-0-c8b53acf4a9bea91d0d99979262194de)
Table 4.8.44(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_496.jpg?sign=1738969439-GonsiPm6Gnnfxs2tSnmheTFwTYjWJWbi-0-239c81e188b811aa8f41a2a3ed343213)
4.8.45 Erection of overflow pump.
1 Scope:erection of such type of water pumps.
2 Quality criteria and inspection methods are shown in Table 4.8.45.
Table 4.8.45 Erection of overflow pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_497.jpg?sign=1738969439-bdls00Ht6XoFpdieM9T40jOuPmcS1S4j-0-b823fee04b15d8265a10263d4d5fc655)
4.8.46 Erection of flushing pump.
1 Scope:erection of such type of pumps for boiler.
2 Quality criteria and inspection methods are shown in Table 4.8.46.
Table 4.8.46 Erection of flushing pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_498.jpg?sign=1738969439-ISK8IDJMAYGb2M5moX9bO4kkSeVNuq6r-0-f7ced2b7198fd14604479801204df963)
4.8.47 Erection of dredging machine.
1 Scope:erection of dredging machine.
2 Quality criteria and inspection methods are shown in Table 4.8.47.
Table 4.8.47 Erection of dredging machine
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_499.jpg?sign=1738969439-brFYKj7MpsnatOtPnM3IKkk6PThTycUp-0-12fc729a9219f0209136e131d253d8fa)
4.8.48 Erection of gasification fan.
1 Scope:erection of boiler gasification fan.
2 Quality criteria and inspection methods are shown in Table 4.8.48.
Table 4.8.48 Erection of gasification fan
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_500.jpg?sign=1738969439-8OujHivgJjEtsGr1RPT6Uoy7PzG521nC-0-d22f6f7eb5d5280060099d5180379608)
4.8.49 Erection of double-axles mixer.
1 Scope:erection of double-axles mixer.
2 Quality criteria and inspection methods are shown in Table 4.8.49.
Table 4.8.49 Erection of double-axles mixer
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_501.jpg?sign=1738969439-HzH5J6pgGWVKAAv36Dj1Sm14TIkKm7L7-0-78ac9beffc6d396a1e604936f815bd74)
Table 4.8.49(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_502.jpg?sign=1738969439-xVEApxYDOyO1xPSgypLb5vjwpzly7aYz-0-0baad947a228e4ea167ed327d10d8c52)
4.8.50 Erection of concentrator.
1 Scope:erection of concentrator.
2 Quality criteria and inspection methods are shown in Table 4.8.50.
Table 4.8.50 Erection of concentrator
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_503.jpg?sign=1738969439-rT7ARfVPXeKKdTuRRYAoUMxgbFvtJfnD-0-504e6b2648359dea6591511cbaa002e5)
Table 4.8.50(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_504.jpg?sign=1738969439-DRoPiNEX4zvrJg8UqrCdCzXOKd0NbaMn-0-298bf2779871c6794ad3eff13f8ae3c9)
4.8.51 Erection of centrifugal slurry pump.
1 Scope:erection of centrifugal slurry pump.
2 Quality criteria and inspection methods are shown in Table 4.8.51.
Table 4.8.51 Erection of centrifugal slurry pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_505.jpg?sign=1738969439-sNLBdF7d8oNJGHueeaN0q3UyTmYqjxHc-0-c65ecab35d0f0f702fed7d28c0d9c7a5)
Table 4.8.51(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_506.jpg?sign=1738969439-PJ4U6iBRNL7PqRr3hELTdBk7WsO2FnTI-0-8c08a305908986aa6468d1cb33d7866e)
4.8.52 Erection of water spray plunger slurry pump.
1 Scope:erection of water spray plunger slurry pump.
2 Quality criteria and inspection methods are shown in Table 4.8.52.
Table 4.8.52 Erection of water spray plunger slurry pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_507.jpg?sign=1738969439-aa64vAkRzSbbR9pCEr3aWEkFrhqIT3RT-0-0c2dda62b0d11eb36cc469221e4ff9d5)
Table 4.8.52(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_508.jpg?sign=1738969439-zfwhlSPEv7AY1rqt5j8WSJjWc5heJ0mG-0-3d7e6c81c9ccae495d503f9700d57f40)
4.8.53 Erection of water-lsolated slurry pump.
1 Scope:erection of centrifugal slurry pump.
2 Quality criteria and inspection methods are shown in Table 4.8.53.
Table 4.8.53 Erection of water-isolated slurry pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_509.jpg?sign=1738969439-SdeCttC6v6hqNrKUX1kJwrlxtJYY0w4j-0-077fbff837330ce9b62d6bf5bf33f9fd)
4.8.54 Erection of slurry high pressure flushing pump.
1 Scope:erection of slurry high pressure flushing pump.
2 Quality criteria and inspection methods are shown in Table 4.8.54.
Table 4.8.54 Erection of slurry high pressure flushing pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_510.jpg?sign=1738969439-iP82TT055L6jfKuDbTab3mwjx7uB5Izl-0-0851deeae6524f9000da1ad235e635cd)
Table 4.8.54(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_511.jpg?sign=1738969439-qElm7CjTT5EeSh0LLyNaxN8t69G6Hwtb-0-8cddcdcefd708d6256e3baee9ba45d7b)
4.8.55 Erection of oil-isolated mud pump.
1 Scope:erection of oil-isolated mud pump.
2 Quality criteria and inspection methods are shown in Table 4.8.55.
Table 4.8.55 Erection of oil-isolated mud pump
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_512.jpg?sign=1738969439-hAzs7dqtV4ZgbDXiQMq575Y792iv80EK-0-0b3c0db65e6be7635609f536fe66cac2)
Table 4.8.55(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_513.jpg?sign=1738969439-TNCmmt40sLwZ4TQ9yLBKbYr0ASWYw0Eq-0-ed6fed2167e1eb96f2ed94d42e1960cd)
4.8.56 Erection of ash removal pipe-belt conveyer.
1 Scope:erection of ash removal pipe-belt conveyer.
2 Quality criteria and inspection methods are shown in Table 4.8.56.
Table 4.8.56 Erection of ash removal pipe-Belt conveyer
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_514.jpg?sign=1738969439-LOvXxyXKNq6ph8cUvzInut93pRNzbwEH-0-47e0912fe05da083bd72cfaab2c47af8)
Table 4.8.56(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_515.jpg?sign=1738969439-ZsTNqMkHXYa9mSlukv8oJcqLI6voHGxt-0-9b1f8e704cc0c46504e93e6d2bdd27a6)
Table 4.8.56(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_516.jpg?sign=1738969439-fJvWIoUC1qKFrFikzXJ1Zsrk29rIGqHF-0-5b14681b1821bc4208be8e738337d54c)
4.8.57 Erection of roots fan.
1 Scope:erection of roots fan.
2 Quality criteria and inspection methods are shown in Table 4.8.57.
Table 4.8.57 Erection of roots fan
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_517.jpg?sign=1738969439-pLMalYNfFsY94zFolXUCwFvgGQul5DhH-0-5a3ef5db214733d313cf07350ec0611c)
Table 4.8.57(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_518.jpg?sign=1738969439-XIHyhPGJzUGugFDoYqV1ceXoQCsscEFr-0-7889a2e5e04c772d9a64d5e132f71b54)
4.8.58 Maintenance and erection of electric hoist.
1 Scope:erection of all electric hoists at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.58.
Table 4.8.58 Maintenance and erection of electric hoist
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_519.jpg?sign=1738969439-TT6ylpFKzlfkVWbGktZEsalhNUsuipdm-0-13f553e90978a283f9cf03d2071f8f58)
Table 4.8.58(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_520.jpg?sign=1738969439-BqO7A5OaGTOB3579jegtj2pcVrbPjvvA-0-2fd2d683433b7476b8e6e50112919a73)
4.8.59 Electric hoist load test.
1 Scope:load test of all electric hoists at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.59.
Table 4.8.59 Electric Hoist Load Test
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_521.jpg?sign=1738969439-L9PUfw15B1HpN34BiKEVBMjc38HrPEi9-0-dd4a8a5046fbcebca5b36bf6944ec484)
4.8.60 Erection of rails.
1 Scope:erection of lifting machinery rails at boiler side.
2 Quality criterias and inspection methods are shown in Table 4.8.60.
Table 4.8.60 Erection of rails
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_522.jpg?sign=1738969439-lf8fbe0yegt5ewU02lC4thblXrecb6dc-0-c0a601f1561d3dbf7f4b1ed591582547)
Table 4.8.60(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_523.jpg?sign=1738969439-o2cGeDH9NvKuTrL1LuUhl7mNEyrUuky1-0-ddda5df53c7b9c6f6fc498c172b60164)
4.8.61 Assembly and erection of crane bridge.
1 Scope:assembly and erection of bridge crane bridge at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.61.
Table 4.8.61 Assembly and erection of crane bridge
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_524.jpg?sign=1738969439-jBrpdU2q9WaFFjymQLYiltQkNtE2tBlh-0-3a95e55377c4a54e38fd2493efa3f0cc)
Table 4.8.61(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_525.jpg?sign=1738969439-QaKz6SPMzvOZ8d0xjJQcxREySVI58l8Q-0-d9a17008fd9d61e3b99485d4a1d1ff19)
4.8.62 Maintenance and erection of transmission machinery.
1 Scope:maintenance and erection of lifting machinery transmission devices at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.62.
Table 4.8.62 Maintenance and erection of transmission machinery
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_526.jpg?sign=1738969439-yXQub7IMIsdurNxt5qE7XPhp07rly6AY-0-8f6530e9f7e08bfa035055a0e6591045)
4.8.63 Crane no-load/static load test.
1 Scope:no-load/static load test of crane machinery at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.63.
Table 4.8.63 Crane no-load/static load test
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_527.jpg?sign=1738969439-mLt0dx4Wmzq4eY1tkAIkvakUt9TwFgRt-0-557e14f1ba18184d8ad839f53d37927f)
4.8.64 Crane dynamic load test
1 Scope:dynamic load test of crane at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.64.
Table 4.8.64 Crane dynamic load test
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_528.jpg?sign=1738969439-kFtJ756lrof4isKWaVtz881UjoL3w3SY-0-6878487d032bfc6561e2e50cb275483c)
4.8.65 Crane live trial operation.
1 Scope:trial operation of live crane machinery at boiler side.
2 Quality criteria and inspection methods are shown in Table 4.8.65.
Table 4.8.65 Crane live trial operation
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_529.jpg?sign=1738969439-oIm8FTYJUQil1J7CvVtTIgyC9tlnIWTL-0-92266861384ed8cadc5c5961f91a707b)
Table 4.8.65(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_530.jpg?sign=1738969439-lyFwsP9KdaEeXbiENR3D8H8zK90xafTA-0-ea2d408fa458b66111525cc1c7e6b642)
4.8.66 Mandatory provisions implementation inspection sheet of erection subsection project of coal mill.
1 Scope:mandatory provisions implementation inspection of erection subsection project of coal mill of the boiler auxiliary machineries.
2 Mandatory provisions implementation shall meet the requirements of Table 4.8.66.
Table 4.8.66 Implementation inspection sheet of mandatory provisions of erection subsection project of coal mill
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_531.jpg?sign=1738969439-DWOm2HUEx3usHLkSaaE1zJPvpAwmWmu4-0-aa61d2b4e8eb5fa5ea7b1a7b10ea6904)
Table 4.8.66(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_532.jpg?sign=1738969439-gX4iBNc6CfRmJ4VgGM10H5KrD4DpbLOe-0-61c36ef952ba868d07eb3a332e04411b)
4.8.67 Implementation inspection sheet of mandatory provisions of erection subsection project of fan.
1 Scope:mandatory provisions implementation situations inspection of fan erection in the boiler auxiliary machineries.
2 Mandatory provisions implementation situations shall meet the requirements of Table 4.8.67.
Table 4.8.67 Implementation inspection sheet of mandatory provisions of erection subsection project of fan
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_533.jpg?sign=1738969439-7w60TIjyJfIQGXUksz0rUD116WoFHVWd-0-5c79fd171fc6abd8f3a4c995d864be3c)
4.8.68 Implementation inspection sheet of mandatory provisions of erection subsection project of doal feeder.
1 Scope:mandatory provisions implementation situations inspection of erection subsection project of boiler coal feeder.
2 Mandatory provisions implementation situations shall meet the requirements of Table 4.8.68.
Table 4.8.68 Implementation inspection sheet of mandatory provisions of erection subsection project of coal feeder
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_534.jpg?sign=1738969439-HGYF5490mb1SgThuR2YqjNZkxG1zG848-0-666a460319fc396260486b254f34944b)
4.8.69 Implementation inspection sheet of mandatory provisions of erection subsection project of air compressor.
1 Scope:mandatory provisions implementation situations inspection of erection subsection project of air compressor.
2 Mandatory provisions implementation situations shall meet the requirements of Table 4.8.69.
Table 4.8.69 Implementation inspection sheet of mandatory provisions of erection subsection project of air compressor
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_535.jpg?sign=1738969439-4sMJxal7s57qE04sP3mE4C9bbrucK1u9-0-b04185692e1b3e964ace131c1da55cdb)
4.8.70 Mandatory provisions implementation inspection sheet of erection subsection project of pump equipments.
1 Scope:mandatory provisions implementation inspection of erection subsection project of pump equipment in boiler auxiliary machineries.
2 Mandatory provisions implementation shall meet the requirements of Table 4.8.70.
Table 4.8.70 Mandatory provisions implementation inspection sheet of erection subsection project of pump equipments
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_536.jpg?sign=1738969439-OV8gkodRqbv7OQx9WDjitT9E2zp3OJy6-0-9cdfbd217a205d15ce36c737abe029ab)
Table 4.8.70(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_537.jpg?sign=1738969439-QoRdFJelemdvEvJYkQQ8S9QggKApyHTC-0-ef58487032786ca0db2b2ecb6d387f82)
4.8.71 Implementation inspection sheet of mandatory provisions of erection subsection project of ash/slag removal equipment.
1 Scope:mandatory provisions implementation situations inspection of erection subsection project of ash/slag removal equipment in boiler auxiliary machineries.
2 Mandatory provisions implementation situations shall meet the requirements of Table 4.8.71.
Table 4.8.71 Implementation inspection sheet of mandatory provisions of erection subsection project of ash/slag removal equipment
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_538.jpg?sign=1738969439-VYcgbm5zregDl8uRxKngdzHjM5N7j5wk-0-0dc3e80cf10d97d4e52cb20e5edf1743)
Table 4.8.71(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_539.jpg?sign=1738969439-ayGwh71wPafVKkAdDcs3YJlsx7kODRR1-0-f62e002dd25c409a09c7700b0d2653aa)
4.8.72 Implementation inspection sheet of mandatory provisions of erection subsection project of lifting facilities in boiler room.
1 Scope:mandatory provisions implementation situations inspection of erection subsection project of lifting facilities in boiler room.
2 Mandatory provisions implementation situations shall meet the requirements of Table 4.8.72.
Table 4.8.72 Implementation inspection sheet of mandatory provisions of erection subsection project of lifting facilities in boiler room
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_540.jpg?sign=1738969439-SEf745RdtXGr0Ppb0zVkCD9WWac0U2NK-0-f7135851da2e813f2b1615bf97a83be5)
Table 4.8.72(Continued)
![img](https://epubservercos.yuewen.com/4C3AA5/18000637908217806/epubprivate/OEBPS/Images/txt004_541.jpg?sign=1738969439-kMUN2f1taAJxekaDk75fVarezUetOGWp-0-556bedae12ff9e20afb6ef852ed718d3)